Now, let’s take a look at the main window open for the TDG139 GSM Thermostat. This window has a specific tab, which is not present for the rest of the remotes, it is the Function  tab, from this tab it is possible to define all settings for the thermostatic operation, that is the temperature for the relay to click (basically, the temperature to be kept) and the temperature values, i.e. the alarm thresholds that when exceeded make the device send SMS or make notification calls. In the same tab you can find the section for setting the inhibition times corresponding to the only opto isolated input (Boiler input) or the temperature sensor (Temperature alarm). From the same tab, you can ask the remote current settings: just click the option box Request and then click on  Run. You may also request sending the current reading of the sensor (with Run next to  Request measured temperature) and reset the maximum and minimum temperature values registered.

Thermostat Mode

The main program window on the TDG139 presents, on the right, in addition to the Master Numbers  tab, another one named System Status. This tab allows the user to enable monitoring of the remote’s operating parameters, simply by clicking on Enable Status Monitor. This tab is related with the Information tab.

Thermostat Monitor